Place of Origin:Dongguan, Guangdong, China
Material Introduction:The ceramic components of this alumina ceramic metering pump can be made from high-purity alumina (99.5%–99.8% Al2O3). Zirconia-toughened alumina (ZTA) can also be considered for parts subject to wear or impact, such as valve seats and valve cores. The metal components are made from stainless steel. Ceramic and stainless steel grades are selected according to customer drawings and operating conditions.
Functional Features:The high-purity alumina components in this precision metering pump offer high hardness (Mohs 9), wear resistance, and dimensional stability. Sliding and sealing surfaces are finished to the specified roughness. Chemical compatibility is assessed for the intended liquid and operating conditions.
CERAMPRO builds complete pumps to customer drawings. The ceramic components shown in the product photos can also be ordered separately. View Metering Pump Core Components
Application Industries:This industrial dosing pump can be configured for fluid control (precision chemical processing, water treatment, and food and beverage production), petrochemical processing (catalyst dosing and corrosive liquid transfer), biomedical applications (pharmaceutical liquid metering and in vitro diagnostic reagent handling), new energy (precision dosing of lithium-ion battery electrolytes), and semiconductor manufacturing (delivery of ultrapure process chemicals). Explore Ceramic Pump Components
Global OEM Supply:Serving OEM customers in the USA, Germany, Japan, and Europe.
Lead Time:Lead time is confirmed after reviewing the drawings, material requirements, pump configuration, and order quantity.
This precision metering pump delivers controlled volumes of liquid in industrial dosing systems and automated production equipment. It uses 99.5% high-purity alumina ceramic components and stainless steel metal parts. The wear-resistant ceramic components help maintain the fit of the metering assembly through repeated cycles, supporting consistent dosing in applications where variations in the amount dispensed can affect the process.
The values below are for reference. The final specifications for your industrial dosing pump are confirmed against the drawing, pump configuration, and agreed test conditions.
| Parameter | Reference Specification | Notes |
|---|---|---|
| Material Grade | 99.5% high-purity alumina (Al2O3) | Other grades can be reviewed against the drawing and operating conditions. Medical or food-contact requirements are reviewed against the applicable standards and supporting documents. |
| Piston-to-Sleeve Clearance | 0.002–0.005 mm | Reference range for a valveless configuration. Confirm whether the drawing specifies radial or diametral clearance. |
| Surface Roughness (Ra) | ≤ 0.1 µm | Confirm which surfaces require this finish and where they will be measured. |
| Metering Accuracy | ±0.5% or better | Reference target. Confirm the test liquid, dose or flow range, operating pressure, and measurement method for the selected pump. |
| Vickers Hardness | 1600–1800 HV | Reference ceramic material property. Confirm the value and test load for the selected grade. |
| Compressive Strength | 2500–3000 MPa | Reference ceramic material property. The allowable operating pressure is specified for the assembled pump. |
| Chemical Resistance and Cleaning | CIP/SIP compatibility subject to configuration review | Confirm the cleaning or sterilization conditions and the compatibility of wetted materials and seals. |
| Thermal Expansion Coefficient | 8.2 × 10−6/K | Reference value for alumina. Confirm the grade and temperature range. |
| Material | Typical Components | Selection Considerations |
|---|---|---|
| High-Purity Alumina | Pistons, plungers, and mating sleeves | Selected for sliding and mating surfaces that require hardness, wear resistance, and dimensional stability. |
| Zirconia-Toughened Alumina (ZTA) | Selected valve seats, valve cores, and other ceramic parts | An option for parts that need greater fracture toughness under repeated contact or impact. |
| Stainless Steel | Housings, fittings, and other metal parts | The grade is selected to suit the drawing and operating conditions. For wetted parts, review compatibility with the process liquid and cleaning agents. |
Yes. We build complete pumps to customer drawings and specifications. The quotation lists the pump assembly, drive, controls, mounting hardware, and connections included in the order.
Send your drawing or assembly specification, quantity, process liquid and concentration, target flow rate or dose per cycle, operating pressure, and temperature. Include the mounting and connection details if available.
Yes. Send a part drawing or mark the component you need in the product photo, then provide the quantity and any critical dimensions. You can also browse our ceramic pump components.
We agree on the test liquid, dose or flow range, operating conditions, measurement method, and acceptance criteria for the selected pump configuration.
What are the advantages of an alumina ceramic metering pump over a metal pump?
Alumina ceramic components resist wear and help maintain a stable piston-to-sleeve fit for consistent dosing. They can also handle corrosive or high-purity liquids when the pump’s wetted materials are compatible with the fluid and operating conditions.
What fluids can this ceramic metering pump handle? Can it pump liquids containing particles?
This pump is best suited to clean liquids free of suspended particles, including high-purity liquids and corrosive fluids compatible with the pump’s wetted materials. Avoid liquids containing hard suspended particles. The clearance between the ceramic piston and sleeve is very small, and particles entering this gap can jam the piston or scratch the precision sealing surfaces.
What precautions should I take during routine operation and maintenance?
Avoid running the pump dry. Without liquid lubrication, friction can generate heat and damage the components.
If the liquid tends to crystallize or dry out, flush the pump chamber thoroughly before shutdown to prevent deposits from forming inside. If the piston becomes stuck, avoid forcing it to move. Use a compatible solvent to soften the deposits or carefully disassemble the pump for cleaning according to the maintenance instructions.
Contact CERAMPRO for a pump quote with your drawing, operating conditions, order quantity, and delivery destination. We will confirm the scope of supply and lead time.